All product information is provided by the supplier. The National Board of Social Services is not responsible for either contents, origin, flaws and deficiencies, or any kind of damage that may occur from the use of the information. The National Board of Social Services has no authority to endorse products and does not assess the quality of the products. Hide this message.
Romedic RiseAtlas Ceiling hoist
Classification
12 36 12 02 - Stationary hoists fixed to walls, floor or ceiling
The product serie includes 8 products. 6 of these products are discontinued from the supplier.
Specifications summarized
Specifications for the 8 products in the product series. Click a HMI-no. to see all details for a single product.Product 1 - 8 | ||||||||
---|---|---|---|---|---|---|---|---|
Specification/HMI-no. | 79789 | 79790 discont. | 79788 discont. | 79787 | 70640 discont. | 70641 discont. | 70643 discont. | 70642 discont. |
Ingress protection class for water 0-9 (IPX0-IPX9) according to the standard for degrees of protection provided by enclosures (IEC 60529) | IPX0 | IPX2 | IPX2 | IPX0 | IPX4 | IPX4 | IPX4 | IPX4 |
Electrical lifting mechanism | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Electrical horizontal movement | Yes | Yes | Yes | Yes | Yes | No | No | Yes |
Intended fixation to ceiling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to wall(s) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to floor | Yes | Yes | Yes | Yes | No | No | No | No |
Fitted with seat | No | No | No | No | No | No | No | No |
Intended use for swimming pools | No | No | No | No | Yes | Yes | Yes | Yes |
Room covering rail system | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition without manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition with manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Detachable lifting machinery | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
External battery charger | Yes | Yes | Yes | Yes | No | No | No | No |
Charging station at track | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Charging liner | No | No | No | No | No | No | No | No |
Emergency lowering function, electrically operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Emergency lowering function, manually operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
User weight, max (kg) | 205 | 205 | 285 | 285 | 205 | 285 | 285 | 285 |
Max lifting velocity, loaded (m/s) | 0.039 | 0.39 | 0.39 | 0.039 | 0.04 | 0.03 | 0.03 | 0.03 |
Weight of lifting machinery (kg) | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7 | 7 | 7.5 |
Min. distance from ceiling to central suspension point (cm) | 24 | 33 | 33 | 24 | 23 | 23 | 23 | 23 |