All product information is provided by the supplier. The National Board of Social Services is not responsible for either contents, origin, flaws and deficiencies, or any kind of damage that may occur from the use of the information. The National Board of Social Services has no authority to endorse products and does not assess the quality of the products. Hide this message.
M2 Flexi-Tip
Classification
09 12 03 11 - Commode shower chairs with wheels, tilt and electrical functions
The product series contains 2 products.
Specifications summarized
Specifications for the 2 products in the product series. Click a HMI-no. to see all details for a single product.Product 1 - 2 | ||
---|---|---|
Specification/HMI-no. | 53471 | 53472 |
Possibility to change position of armrest to allow sideways transfer | Ja, opklappelige | Ja, opklappelige |
Height adjustable | Manuelt | Manuelt |
Number of wheels with brake | 4 | 4 |
Ingress protection class for water 0-9 (IPX0-IPX9) according to the standard for degrees of protection provided by enclosures (IEC 60529) | IPX6 | IPX6 |
Tension adjustable back rest upholstery | Yes | Yes |
Can be used with standard wall-mounted toilets (without extension) | Yes | Yes |
Intended for children Products for children must comply with the specific demands for safety as stated in certain standards. It is the supplier of the product who has stated that the product is intended for children. The National Board of Social Services holds no responsibility in relation to this assessment. | No | No |
Powered tilt | Yes | Yes |
Tilt-in-space dissociated from the height adjustment The function of the tilt-in-space is separated from the hydraulic or electrical function of the height adjustment. | Yes | Yes |
Head support | Yes | Yes |
Battery chargeable separated from the product | Yes | Yes |
Emergency stopping function | No | No |
Fold-up foot supports | Yes | Yes |
Height adjustable legrests | Yes | Yes |
Elevating legrests | Yes | Yes |
Removable legrests | Yes | Yes |
Pivoting legrests | Yes | Yes |
Legrest position may be changed to facililtate hygiene and transfer | Yes | Yes |
User weight, max (kg) | 125 | 125 |
Total width (cm) | 59 | 59 |
Ground clearance (cm) Measured from the floor to the lowest point under the seat. Measured without bedpan/collection receptacle. | 52.5 | 52.5 |
Width between arm supports (cm) Smallest distance measured between the inside of the armrests | 46 | 46 |
Seat depth (cm) | 44 | 44 |
Toilet opening width (cm) | 22 | 22 |
Seat height, min (cm) | 55.5 | 55.5 |
Seat height, max (cm) | 61.5 | 61.5 |
Tilt-in-space forward (°) Measured from the horizontal position. | 7 | 7 |
Tilt-in-space back (°) Measured from the horizontal position. | 37 | 37 |
Wheel diameter (mm) | 125 | 125 |
Height of push handles/push bar, min. (cm) Measured from the floor to the upper surface of the grip. According to ISO 17966:2016 it shall be possible to push the chair with the grip 90 cm above the floor. | 100 | 100 |
Height of push handles/push bar, max. (cm) Measured from the floor to the upper surface of the heigher grip with the chair in the highest position | 106 | 106 |