All Up Elbow



Positioning cushion for elbow pressure relief.
For users at risk of pressure, especially with reduced arm function.
Prevents and relieves pressure ulcers through even pressure distribution around the elbow.
Especially suitable for hemiparesis or hemiplegia.
Inflatable cushion with skin-friendly, moisture-absorbing nonwoven felt. (CE/MDR 2017)

Classification
09 07 06 06 - Positioning cushions for legs and arms

Documents


The product series includes 2 products of which 1 product is discontinued.

Product 1 of 2
All Up Elbow


HMI-no.
Article-no.
70028

Registration date
01-02-2016
Last updated
19-01-2026

Properties
Shape
Anden udformning
Filling
Luft
(Optional) machine washable cover
No
(Optional) cover which can be autoclaved
No
(Optional) cover which can be disinfected
No
Machine washable cushion
No
Cushion can be autoclaved
No
Cushion can be tumble dried
No
Flame resistant
No
For arm or hand
Yes
For leg or foot
No

Measures
Height
10
cm
Longest side
30
cm
Shortest side
20
cm

Test information
No information about tests according to standards
The supplier has not provided documentation, that this product is testet according to a relevant standard. See examples of relevant standards for this product type

EU product safety regulation 
The supplier has provided the following information about CE-marking of the product. Explain CE-marking
CE marked as medical device

Product 2 of 2
All Up Elbow medium

The product was discontinued from Levabo ApS 20-01-2026


HMI-no.
134033
Article-no.
70048

Registration date
18-10-2022
Last updated
20-01-2026

Properties
Shape
Rendeformet
Filling
Luft
(Optional) machine washable cover
Yes
(Optional) cover which can be autoclaved
No
(Optional) cover which can be disinfected
Yes
Machine washable cushion
Yes
Cushion can be autoclaved
No
Cushion can be tumble dried
No
Flame resistant
No
For arm or hand
Yes
For leg or foot
No

Measures
Height
10
cm
Longest side
23
cm
Shortest side
20
cm

Test information 
Though the product is testet, it might not have passed all requirements in the standard. Besides, some products are only tested according to parts of the standard. Read the test report for detailed information. See also other standards that could be relevant for this product type.
: Tested according to other national or international standard.
Test lab: BEO Berlin. Test date: 23-08-2019 Test report for HMI-no. 134033

EU product safety regulation 
The supplier has provided the following information about CE-marking of the product. Explain CE-marking
CE marked as medical device