All product information is provided by the supplier. The National Board of Social Services is not responsible for either contents, origin, flaws and deficiencies, or any kind of damage that may occur from the use of the information. The National Board of Social Services has no authority to endorse products and does not assess the quality of the products. Hide this message.
GH3 Lifting module
GH3 ceiling mounted system is easy to understand & use. Lifting procedures is done safe & comfortable for all. GH3 with the timeless design can be optimally adapted to individual needs both in terms of function, specifications & investment budget. Can lift up to 350 kg with 1 hanger & 500 kg with 2 straps with a lifting speed up to 60 mm / sec
Classification
12 36 12 02 - Stationary hoists fixed to walls, floor or ceiling
Video
The product series contains 20 products.
The product series also includes 19 discontinued products. Include discontinued products.
Specifications summarized
Specifications for the 20 products in the product series. Click a HMI-no. to see all details for a single product.Product 1 - 10 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Specification/HMI-no. | 140234 | 52440 | 69383 | 74344 | 140237 | 54612 | 140240 | 140231 | 54617 | 140228 |
Ingress protection class for water 0-9 (IPX0-IPX9) according to the standard for degrees of protection provided by enclosures (IEC 60529) | IPX0 | IPX0 | IPX0 | IPX0 | IPX0 | IPX9 | IPX9 | IPX0 | IPX9 | IPX0 |
Electrical lifting mechanism | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Electrical horizontal movement | No | No | No | Yes | Yes | No | No | Yes | No | No |
Intended fixation to ceiling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to wall(s) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to floor | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Fitted with seat | No | No | No | No | No | No | No | No | No | No |
Intended use for swimming pools | Yes | Yes | Yes | Yes | Yes | Yes | No | No | Yes | No |
Room covering rail system | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition without manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition with manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Detachable lifting machinery | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
External battery charger | No | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | No |
Charging station at track | No | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | No |
Charging liner | Yes | Yes | Yes | Yes | No | Yes | No | Yes | Yes | Yes |
Emergency lowering function, electrically operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Emergency lowering function, manually operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
User weight, max (kg) | 200 | 200 | 200 | 200 | 200 | 250 | 250 | 250 | 300 | 350 |
Max lifting velocity, loaded (m/s) | 0.04 | 0.04 | 0.04 | 0.04 | 0.04 | 0.06 | 0.06 | 0.04 | 0.06 | 0.04 |
Weight of lifting machinery (kg) | 9.6 | 9.6 | 9.6 | 9.6 | 9.6 | 9.6 | 9.6 | 9.6 | 14.2 | 9.6 |
Min. distance from ceiling to central suspension point (cm) | 26.6 | 26.6 | 26.6 | 26.6 | 26.6 | 52.7 | 52.7 | 26.6 | 52.7 | 26.6 |
Maintenance frequency (måneder) | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
Product 11 - 20 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Specification/HMI-no. | 105369 | 140243 | 114885 | 140252 | 140255 | 85016 | 54618 | 140246 | 140249 | 54625 |
Ingress protection class for water 0-9 (IPX0-IPX9) according to the standard for degrees of protection provided by enclosures (IEC 60529) | IPX9 | IPX9 | - | IPX0 | IPX0 | IPX0 | IPX9 | IPX9 | IPX9 | IPX9 |
Electrical lifting mechanism | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Electrical horizontal movement | No | No | No | No | No | Yes | No | No | No | No |
Intended fixation to ceiling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to wall(s) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to floor | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Fitted with seat | No | No | No | No | No | No | No | No | No | No |
Intended use for swimming pools | Yes | No | Yes | No | No | Yes | Yes | No | No | Yes |
Room covering rail system | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition without manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition with manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Detachable lifting machinery | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
External battery charger | Yes | No | No | No | No | Yes | Yes | No | No | Yes |
Charging station at track | Yes | No | No | No | No | Yes | Yes | No | No | Yes |
Charging liner | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Emergency lowering function, electrically operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Emergency lowering function, manually operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
User weight, max (kg) | 375 | 250 | 250 | 250 | 250 | 250 | 300 | 350 | 350 | 500 |
Max lifting velocity, loaded (m/s) | 0.06 | 0.06 | 0.06 | 0.06 | 0.06 | 0.04 | 0.06 | 0.06 | 0.06 | 0.06 |
Weight of lifting machinery (kg) | 14.2 | 9.6 | 10.2 | 9.6 | 9.6 | 9.6 | 14.2 | 9.6 | 9.6 | 19.2 |
Min. distance from ceiling to central suspension point (cm) | 52.7 | 52.7 | 26.6 | 52.7 | 52.7 | 26.6 | 52.7 | 52.7 | 52.7 | 52.7 |
Maintenance frequency (måneder) | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |