All product information is provided by the supplier. The National Board of Social Services is not responsible for either contents, origin, flaws and deficiencies, or any kind of damage that may occur from the use of the information. The National Board of Social Services has no authority to endorse products and does not assess the quality of the products. Hide this message.
Telescopic ramp
Classification
18 30 15 08 - Track ramps
Documents
The product series contains 3 products.
Product 1 of 3
tm 300
HMI-no.
Article-no.
TM-300
Registration date
13-03-2017
Last updated
05-12-2024
Properties
Foldable
Yes
Length adjustable
Yes
Non-slip surface
Yes
Indoor use
Yes
Outdoor use
Yes
Lip, top
Yes
Lip, bottom
No
Carrying handle
Yes
Measures
Load, max
250
kg
For both track ramps and ramps please state the allowed load pr. item.
Weight
17.3
kg
Weight per track
Actual length in use, min
300
cm
The minimum length in use of the track excluding lips
Actual length in use, max
300
cm
The maximum length in use of the track excluding lips
Transportation length
108
cm
Transportation width
26
cm
Internal width
19.5
cm
External width
26
cm
Guardrail height
5
cm
Test information 
Though the product is testet, it might not have passed all requirements in the standard. Besides, some products are only tested according to parts of the standard. Read the test report for detailed information. See also other standards that could be relevant for this product type.
EN 12182:2012: Assistive products for persons with disability - General requirements and test methods.
Test lab: Centre For Testing And Certification - Mech-Test. Test date: 20-05-2013
Test report for HMI-no. 104834
Test lab: Centre For Testing And Certification - Mech-Test. Test date: 20-05-2013
EU product safety regulation 
The supplier has provided the following information about CE-marking of the product. Explain CE-marking
CE marked as medical device
Product 2 of 3
TM-150 ramp
HMI-no.
Article-no.
tm-150
Registration date
13-03-2017
Last updated
04-11-2024
Properties
Foldable
No
Length adjustable
Yes
Non-slip surface
Yes
Indoor use
Yes
Outdoor use
Yes
Lip, top
Yes
Lip, bottom
No
Carrying handle
Yes
Measures
Load, max
300
kg
For both track ramps and ramps please state the allowed load pr. item.
Weight
7.9
kg
Weight per track
Actual length in use, min
150
cm
The minimum length in use of the track excluding lips
Actual length in use, max
150
cm
The maximum length in use of the track excluding lips
Transportation length
98
cm
Transportation width
27
cm
Internal width
19.5
cm
External width
25
cm
Guardrail height
5
cm
Test information
No information about tests according to standards 
The supplier has not provided documentation, that this product is testet according to a relevant standard. See examples of relevant standards for this product type
EU product safety regulation 
The supplier has provided the following information about CE-marking of the product. Explain CE-marking
CE marked as medical device
Product 3 of 3
tm-210
HMI-no.
Article-no.
tm-210
Registration date
13-03-2017
Last updated
05-12-2024
Properties
Foldable
No
Length adjustable
Yes
Non-slip surface
Yes
Indoor use
Yes
Outdoor use
Yes
Lip, top
Yes
Lip, bottom
No
Carrying handle
Yes
Measures
Load, max
300
kg
For both track ramps and ramps please state the allowed load pr. item.
Weight
11.6
kg
Weight per track
Actual length in use, min
210
cm
The minimum length in use of the track excluding lips
Actual length in use, max
210
cm
The maximum length in use of the track excluding lips
Transportation length
128
cm
Transportation width
27
cm
Internal width
19.5
cm
External width
25
cm
Guardrail height
5
cm
Test information 
Though the product is testet, it might not have passed all requirements in the standard. Besides, some products are only tested according to parts of the standard. Read the test report for detailed information. See also other standards that could be relevant for this product type.
EN 12182:2012: Assistive products for persons with disability - General requirements and test methods.
Test lab: Centre For Testing And Certification - Mech-Test. Test date: 20-05-2013
Test report for HMI-no. 104833
Test lab: Centre For Testing And Certification - Mech-Test. Test date: 20-05-2013
EU product safety regulation 
The supplier has provided the following information about CE-marking of the product. Explain CE-marking
CE marked as medical device