All product information is provided by the supplier. The National Board of Social Services is not responsible for either contents, origin, flaws and deficiencies, or any kind of damage that may occur from the use of the information. The National Board of Social Services has no authority to endorse products and does not assess the quality of the products. Hide this message.

Tiger outdoor rollator med underarmsstøtte


Classification
12 06 12 07 - Walking tables with separated forearm supports



The product series contains 1 product.

Product 1 of 1
Tiger outdoor rollator med underarmsstøtte


HMI-no.
Article-no.
312205( grå)312206(brun)

Registration date
19-08-2019
Last updated
21-11-2023

Properties
Intended for children
No
info
Products for children must comply with the specific demands for safety as stated in certain standards. It is the supplier of the product who has stated that the product is intended for children. The National Board of Social Services holds no responsibility in relation to this assessment.
Indoor use
Yes
Outdoor use
Yes
Resting seat
Yes
Foldable
Yes
Provided with basket
Yes

Measures
Height support unit, min
87
cm
Height support unit, max
110
cm
Length, max
77
cm
Weight
12
kg
User weight, max
200
kg
External width, max
71
cm
Internal width, max
56
cm
info
Measured between the forearm supports.
Seat height, min
62
cm
Seat height, max
62
cm

Test information info
Though the product is testet, it might not have passed all requirements in the standard. Besides, some products are only tested according to parts of the standard. Read the test report for detailed information. See also other standards that could be relevant for this product type.
EN ISO 11199-3:2005: Walking aids manipulated by both arms - Requirements and test methods. Part 3: Walking tables.
Test lab: CBC, Warszawa, Polen. Test date: 27-11-2017 Test report for HMI-no. 119027

EU product safety regulation 
No information about CE-marking info
The supplier has not provided any information about CE-marking of the product. Explain CE-marking